Performance

The Multi-X design allows you to use a working pressure up to 35 MPa on half the ports simultaneously and the rest of the ports as return lines with a maximum of 5 MPa, regardless if you use two or four ports.
The design also offers the possibility to connect the units with residual pressure.
Residual pressure
-
Up to 35 MPa residual pressure on the male side when free to drain on the female side.
-
Up to 25 MPa residual pressure on the female side when free to drain on the male side.
-
Up to 25 MPa residual pressure on the male side and 1 MPa return resistance on the female side.